The Camplate Tool allows the engine builder to know what psi the relief valve opens and lets you adjust spring tension to achieve the desired pop-off psi. 🔧
- Tool includes:
- Air regulator
- 0-100 psi pressure gauge
- Gasket and needed hardware
- Made in the USA
- Feuling® recommends the cam plate valve be seated 0-30 psi with full pop off at 55-60 psi.
Bench test the cam plate before installation: cycle the pressure relief valve, verify operation and assure the valve moves freely, seats and seals each time. Any leakage at the relief valve will reduce oil pressure. ✅
EU: Feuling® recommends the cam plate valve be seated 0-2,06 bar with full pop off at 3,79 bar - 4,13 bar.
The camplate psi tester fits all Twin Cam camplates, factory and aftermarket; '07-'17 camplates will have 1 un-used bolt hole.